AL SERIES

FLEXIBLE EQUIPMENT

Laser Source AL

The AL laser system is the most versatile device in our product range in terms of laser source, laser power, and equipment.

Lasers of the AL series can be individually configured and perfectly matched to the tasks. These are available as flash-lamp pumped lasers with outputs between 75 – 500 watts or as fiber lasers with outputs of 300, 450, 600, and 900 W. 

Thousands of users depend on the reliable pulse-to-pulse behavior of the flash-lamp pumped laser and the high laser power that actually gets to the workpiece.

<div/>

The laser systems can be integrated into existing machinery or used in conjunction with our AL-T work benches as a flexible professional solution.

We also offer a wide range of processing objectives for the AL. Whether you work with standard objectives, a 90° deflection objective, or a circular welding lens: the laser beam always precisely hits the desired spot on the workpiece.

Your benefits at a glance:

  • Flexible use
  • Laser power of 75 – 500 watts with a single Nd:YAG laser source
  • Laser power of 300 – 900 W with a fiber laser source
  • Combinable with different table systems
  • Can be integrated in machinery
  • Robust and durable
  • Many accessories
Advantages

Work Benches for Laser Welding Devices of the AL Series

The stability of the movement system is critical to achieving optimal welding results.
Precise focusing of the laser is only possible when a high degree of stability is given.
Our laser work benches are particularly stable.

 

AL-T Basis

   For flexible work

AL-T 500

   For programmed laser welding

ALFlak Movement System

   Ideal for use with the AL 500

ALT Basis CAN

Table for fiber lasers



to the detailed product description of the work benches

Select Between a Flash-Lamp Pumped AL Nd:AG
or an AL with Fiber Laser Source.

  • AL-Nd:YAG
  • AL fiber
  • AL 75
  • AL 120
  • AL 150
  • AL 200
  • AL 300
  • AL 500
    • Laser
      Laser type / wavelengthNd:YAG, 1064 nm
      Average power75 W
      Peak pulse power7 kW
      Pulse energy60 J
      Pulse duration0.5 – 20 ms
      Pulse frequency-50 Hz
      Operating modePulsed
      Welding spot Ø0.2 – 2.0 mm With micro welding function (optional) < 100 µm
      Focusing objective150 mm, further ones according to lens data sheet
      Pulse shapingAdjustability of power curve within a laser pulse
      Display and operationDisplay with membrane keyboard Laser parameters can also be set using a multifunctional footswitch.
      Interface for control of WINLaserNC software via external PC
    • Observation lens
      Leica microscope attachment with oculars for wearers of glasses, 10x Optional 16x
    • Power supply unit
      W × D × H (basic component)820 x 400 x 910 mm
      Weight120 kg
    • Laser beam source
      With focusing unit (length x Ø)900 x 120 mm
      Weightapprox. 18 kg
    • External connections
      Electrical connection200-240 V / 50-60 Hz / 16 A
    • Laser
      Laser type / wavelengthNd:YAG, 1064 nm
      Average power120 W
      Peak pulse power9 kW
      Pulse energy75 J
      Pulse duration0.5 – 20 ms
      Pulse frequency-50 Hz
      Operating modePulsed
      Welding spot Ø0.2 – 2.0 mm With micro welding function (optional) < 100 µm
      Focusing objective150 mm, further ones according to lens data sheet
      Pulse shapingAdjustability of power curve within a laser pulse
      Display and operationDisplay with membrane keyboard Laser parameters can also be set using a multifunctional footswitch.
      Interface for control of WINLaserNC software via external PC
    • Observation lens
      Leica microscope attachment with oculars for wearers of glasses, 10x Optional 16x
    • Power supply unit
      W × D × H (basic component)820 x 400 x 910 mm
      Weight120 kg
    • Laser beam source
      With focusing unit (length x Ø)900 x 120 mm
      Weightapprox. 18 kg
    • External connections
      Electrical connection200-240 V / 50-60 Hz / 16 A
    • Laser
      Laser type / wavelengthNd:YAG, 1064 nm
      Average power150 W
      Peak pulse power9 kW
      Pulse energy75 J
      Pulse duration0.5 – 20 ms
      Pulse frequency-100 Hz
      Operating modePulsed
      Welding spot Ø0.2 – 2.0 mm With micro welding function (optional) < 100 µm
      Focusing objective150 mm, further ones according to lens data sheet
      Pulse shapingAdjustability of power curve within a laser pulse
      Display and operationDisplay with membrane keyboard Laser parameters can also be set using a multifunctional footswitch.
      Interface for control of WINLaserNC software via external PC
    • Observation lens
      Leica microscope attachment with oculars for wearers of glasses, 10x Optional 16x
    • Power supply unit
      W × D × H (basic component)820 x 400 x 910 mm
      Weight120 kg
    • Laser beam source
      With focusing unit (length x Ø)900 x 120 mm
      Weightapprox. 18 kg
    • External connections
      Electrical connection3 x 400 V / 50-60 Hz / 3 x 16 A
    • Laser
      Laser type / wavelengthNd:YAG, 1064 nm
      Average power200 W
      Peak pulse power9 kW
      Pulse energy90 J
      Pulse duration0.5 – 20 ms
      Pulse frequency-100 Hz
      Operating modePulsed
      Welding spot Ø0.2 – 2.0 mm With micro welding function (optional) < 100 µm
      Focusing objective150 mm, further ones according to lens data sheet
      Pulse shapingAdjustability of power curve within a laser pulse
      Display and operationDisplay with membrane keyboard Laser parameters can also be set using a multifunctional footswitch.
      Interface for control of WINLaserNC software via external PC
    • Observation lens
      Leica microscope attachment with oculars for wearers of glasses, 10x Optional 16x
    • Power supply unit
      W × D × H (basic component)820 x 400 x 910 mm
      Weight120 kg
    • Laser beam source
      With focusing unit (length x Ø)1100 x 120 mm
      Weightapprox. 20 kg
    • External connections
      Electrical connection3 x 400 V / 50-60 Hz / 3 x 16 A
    • Laser
      Laser type / wavelengthNd:YAG, 1064 nm
      Average power300 W
      Peak pulse power9 kW
      Pulse energy90 J
      Pulse duration0.5 – 20 ms
      Pulse frequency-100 Hz
      Operating modePulsed
      Welding spot Ø0.2 – 2.0 mm With micro welding function (optional) < 100 µm
      Focusing objective150 mm, further ones according to lens data sheet
      Pulse shapingAdjustability of power curve within a laser pulse
      Display and operationDisplay with membrane keyboard Laser parameters can also be set using a multifunctional footswitch.
      Interface for control of WINLaserNC software via external PC
    • Observation lens
      Leica microscope attachment with oculars for wearers of glasses, 10x Optional 16x
    • Power supply unit
      W × D × H (basic component)820 x 400 x 910 mm
      Weight120 kg
    • Laser beam source
      With focusing unit (length x Ø)1100 x 120 mm
      Weightapprox. 20 kg
    • External connections
      Electrical connection3 x 400 V / 50-60 Hz / 3 x 16 A
      External cooling systemPrepared
    • Laser
      Laser type / wavelengthNd:YAG, 1064 nm
      Average power500 W
      Peak pulse power15 kW
      Pulse energy100 J
      Pulse duration0.5 – 20 ms
      Pulse frequency-100 Hz
      Operating modePulsed
      Welding spot Ø0.2–2 / 0.5–2.5 / 1.0–3 mm
      Focusing objective150 mm, further ones according to lens data sheet
      Pulse shapingAdjustability of power curve within a laser pulse
      Display and operationDisplay with membrane keyboard Laser parameters can also be set using a multifunctional footswitch.
      Interface for control of WINLaserNC software via external PC
    • Observation lens
      Leica microscope attachment with oculars for wearers of glasses, 10x Optional 16x
    • Power supply unit
      W × D × H (basic component)1060 x 570 x 1000 mm
      Weight180 kg
    • Laser beam source
      With focusing unit (length x Ø)800 x 120 mm
      Weightapprox. 25 kg
    • External connections
      Electrical connection3 x 400 V / 50-60 Hz / 3 x 32 A
      External cooling systemrequired
  • Download brochure
  • AL-Nd:YAG
  • AL fiber
  • AL 300 F
  • AL 450 F
  • AL 600 F
  • AL 900 F
    • Laser
      Laser type / wavelengthFiber laser, 1070 nm
      Average power300 W
      CW output300 W
      Peak pulse power3 kW
      Pulse energy30 J
      Pulse duration0.2 ms – CW
      Pulse frequencySingle pulse – 100 Hz
      Beam parameter product at 50 µm5 – 15 mm * mrad
      Operating modesPulsed / CW
      Welding spot Ø0.1 – 3.0 mm
      Focusing objective150 mm, further ones according to lens data sheet
      Pulse shapingAdjustability of power curve within a laser pulse
      Display and operationLaser parameters set through touchscreen or multifunctional footswitch
      AL-T Basis C triggered through laser touchscreen
    • Observation lens
      Leica microscope attachment with oculars for wearers of glasses, 10x Optional 16x
    • External dimensions
      Power supply unit W × D × H550 x 600 x 1200 mm
      Weightapprox. 100 kg
    • Laser beam source
      With focusing unit (length x Ø)because various lenses are possible upon request
    • Electrical connections
      Electrical connection200-240 V / 50-60 Hz / 16 A
    • Laser
      Laser type / wavelengthFiber laser, 1070 nm
      Average power450 W
      CW output450 W
      Peak pulse power4.5 kW
      Pulse energy45 J
      Pulse duration0.2 ms – CW
      Pulse frequencySingle pulse – 100 Hz
      Beam parameter product at 50 µm5 – 15 mm * mrad
      Operating modesPulsed / CW
      Welding spot Ø0.1 – 3.0 mm
      Focusing objective150 mm, further ones according to lens data sheet
      Pulse shapingAdjustability of power curve within a laser pulse
      Display and operationLaser parameters set through touchscreen or multifunctional footswitch
      AL-T Basis C triggered through laser touchscreen
    • Observation lens
      Leica microscope attachment with oculars for wearers of glasses, 10x Optional 16x
    • External dimensions
      Power supply unit W × D × H550 x 600 x 1200 mm
      Weightapprox. 100 kg
    • Laser beam source
      With focusing unit (length x Ø)because various lenses are possible upon request
    • Electrical connections
      Electrical connection200-240 V / 50-60 Hz / 16 A
    • Laser
      Laser type / wavelengthFiber laser, 1070 nm
      Average power600 W
      CW output600 W
      Peak pulse power6 kW
      Pulse energy60 J
      Pulse duration0.2 ms – CW
      Pulse frequencySingle pulse – 100 Hz
      Beam parameter product at 50 µm5 – 15 mm * mrad
      Operating modesPulsed / CW
      Welding spot Ø0.3 – 4.0 mm
      Focusing objective150 mm, further ones according to lens data sheet
      Pulse shapingAdjustability of power curve within a laser pulse
      Display and operationLaser parameters set through touchscreen or multifunctional footswitch
      AL-T Basis C triggered through laser touchscreen
    • Observation lens
      Leica microscope attachment with oculars for wearers of glasses, 10x Optional 16x
    • External dimensions
      Power supply unit W × D × H550 x 600 x 1200 mm
      Weightapprox. 100 kg
    • Laser beam source
      With focusing unit (length x Ø)because various lenses are possible upon request
    • Electrical connections
      Electrical connection3 x 400 V / 50-60 Hz / 3 x 16 A
      External cooling systemLens water cooling integrated
    • Laser
      Laser type / wavelengthFiber laser, 1070 nm
      Average power900 W
      CW output900 W
      Peak pulse power9 kW
      Pulse energy90 J
      Pulse duration0.2 ms – CW
      Pulse frequencySingle pulse – 100 Hz
      Beam parameter product at 50 µm5 – 15 mm * mrad
      Operating modesPulsed / CW
      Welding spot Ø0.3 – 4.0 mm
      Focusing objective150 mm, further ones according to lens data sheet
      Pulse shapingAdjustability of power curve within a laser pulse
      Display and operationLaser parameters set through touchscreen or multifunctional footswitch
      AL-T Basis C triggered through laser touchscreen
    • Observation lens
      Leica microscope attachment with oculars for wearers of glasses, 10x Optional 16x
    • External dimensions
      Power supply unit W × D × H550 x 600 x 1200 mm
      Weightapprox. 100 kg
    • Laser beam source
      With focusing unit (length x Ø)because various lenses are possible upon request
    • Electrical connections
      Electrical connection3 x 400 V / 50-60 Hz / 3 x 16 A
      External cooling systemLens water cooling integrated
  • Download brochure

Technical accessories